        What is the meaning of constant power and constant torque in variable frequency speed regulation?

        2023-05-20 11:21:22

        Generally speaking, the factory motor is based on a given power-frequency voltage (380V, 50hz) to obtain the rated speed value. If it does not reach 380V under actual working conditions, such as only 300V and 50hz, the voltage is obviously under pressure. Basically, it can't reach the rated speed because, depending on the design of the motor, it must have a voltage of 380V and a frequency of 50hz. To excite, at the rated voltage, the magnetic field strength is not up to, and the magnetic flux is very small, so it will definitely affect the speed, not because of the 60f/p formula to see the speed change. For example, in the case of 380V 40Hz input, according to the formula E=K*F*Q, E remains unchanged and F decreases, then Q flux increases. This is a case of overvoltage. Too much excitation will cause the motor to heat up and possibly burn out over a long period of time. Therefore, the value of magnetic flux should not be too large, which is determined by the bearing capacity of the motor in design. Usually at constant torque speeds (below 50 hz), the magnetic flux at this point is the rated magnetic flux, also known as the full magnetic flux. If the voltage/frequency increases, it will exceed the flux value, causing the motor to heat up.


        Constant torque speed control:


        In other words, let the flux be constant, v over f is equal to q is constant. Why is it called constant torque speed regulation? In other words, the load torque is a fixed value, and so is the motor output torque. See formula: t = k * I * q, when q is constant, the motor output torque is proportional to the I, because the value of q can through the nameplate V (rated voltage) / 50 hz to calculate, so when the q is constant, the rated current of the coil (regardless of whether there is a load, by determining the largest current, can also determine the maximum torque of the motor output (can also determine how much torque motor to drive the constant load), so the motor over-current capacity reflects the overload capacity (torque).


        The following provides a constant torque speed, which only needs to be delivered by the inverter through a motor modulated by a voltage at a certain frequency (magnetic flux, the ratio of predetermined values). The load torque is also a fixed value, so the constant N, T and of course, the input power P are therefore fixed. If F increases and the speed N increases, the power P will increase, because the torque T will not increase due to the increase in speed (this is also known as a constant torque load, such as a conveyor belt. Constant torque characteristics are independent of load torque and speed, where torque remains constant or substantially constant at any speed in general applications, such as conveyor belt, mixer, or extruder type friction load and crane, hoisting potential load, etc.)


        Another point is that the rated speed is the value obtained when the motor is idling. For the meaning of this value, when the rated voltage and rated power are reached, the larger the value, the smaller the output torque. This is a characteristic of constant power speed regulation. Formula T=9550*P/N(rated speed). Therefore, in the case of f-type 50Hz(when the output power is the maximum), when n is large, attention should be paid to the fact that T is small to avoid accidents caused by T being too small and smaller than the load torque. In constant power speed regulation, speed regulation is achieved by reducing the magnetic flux to reduce the output torque and thus increase the speed, so it is also known as weak magnetic speed regulation.

        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標題-8.png 0755-81719517
        未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
        未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
        主站蜘蛛池模板: 69天堂人成无码免费视频| 亚洲av无码牛牛影视在线二区 | 黑人一区二区三区在线| 亚洲丰满老熟女激情av| 国产精品国产三级国快看| 欧美成人精品三级网站下载| 四虎成人在线观看免费| 少妇顶级牲交免费在线| 日韩一区二区在线看精品| WWW丫丫国产成人精品| 无码无需播放器av网站| 欧美视频在线播放观看免费福利资源| 国精偷拍一区二区三区| 色狠狠色噜噜AV一区| 亚洲午夜无码av毛片久久| 日韩熟妇中文色在线视频| 无码中文字幕乱在线观看| 日本久久一区二区免高清| 亚洲欧美日韩久久一区二区| 91人妻熟妇在线视频| 中文字幕在线看视频一区二区三区| 国产私拍大尺度在线视频| av深夜免费在线观看| 国产人妻鲁鲁一区二区| 亚洲人成电影在线天堂色| 日本精品人妻无码77777| 国产午夜福利小视频在线| 成年18禁美女网站免费进入| 视频一区二区三区自拍偷拍| 国产欧美日韩精品第二区| 国产欧美久久一区二区| 99人体免费视频| 福利一区二区不卡国产| 欧美肥老太wbwbwbb| 成人中文在线| 窝窝午夜色视频国产精品破| 亚洲综合激情六月婷婷在线观看 | 国内精品视频一区二区三区| 久久精品夜夜夜夜夜久久| 亚洲一二三区精品美妇| 国产福利2021最新在线观看|