        What is the meaning of constant power and constant torque in variable frequency speed regulation?

        2023-05-20 11:21:22

        Generally speaking, the factory motor is based on a given power-frequency voltage (380V, 50hz) to obtain the rated speed value. If it does not reach 380V under actual working conditions, such as only 300V and 50hz, the voltage is obviously under pressure. Basically, it can't reach the rated speed because, depending on the design of the motor, it must have a voltage of 380V and a frequency of 50hz. To excite, at the rated voltage, the magnetic field strength is not up to, and the magnetic flux is very small, so it will definitely affect the speed, not because of the 60f/p formula to see the speed change. For example, in the case of 380V 40Hz input, according to the formula E=K*F*Q, E remains unchanged and F decreases, then Q flux increases. This is a case of overvoltage. Too much excitation will cause the motor to heat up and possibly burn out over a long period of time. Therefore, the value of magnetic flux should not be too large, which is determined by the bearing capacity of the motor in design. Usually at constant torque speeds (below 50 hz), the magnetic flux at this point is the rated magnetic flux, also known as the full magnetic flux. If the voltage/frequency increases, it will exceed the flux value, causing the motor to heat up.


        Constant torque speed control:


        In other words, let the flux be constant, v over f is equal to q is constant. Why is it called constant torque speed regulation? In other words, the load torque is a fixed value, and so is the motor output torque. See formula: t = k * I * q, when q is constant, the motor output torque is proportional to the I, because the value of q can through the nameplate V (rated voltage) / 50 hz to calculate, so when the q is constant, the rated current of the coil (regardless of whether there is a load, by determining the largest current, can also determine the maximum torque of the motor output (can also determine how much torque motor to drive the constant load), so the motor over-current capacity reflects the overload capacity (torque).


        The following provides a constant torque speed, which only needs to be delivered by the inverter through a motor modulated by a voltage at a certain frequency (magnetic flux, the ratio of predetermined values). The load torque is also a fixed value, so the constant N, T and of course, the input power P are therefore fixed. If F increases and the speed N increases, the power P will increase, because the torque T will not increase due to the increase in speed (this is also known as a constant torque load, such as a conveyor belt. Constant torque characteristics are independent of load torque and speed, where torque remains constant or substantially constant at any speed in general applications, such as conveyor belt, mixer, or extruder type friction load and crane, hoisting potential load, etc.)


        Another point is that the rated speed is the value obtained when the motor is idling. For the meaning of this value, when the rated voltage and rated power are reached, the larger the value, the smaller the output torque. This is a characteristic of constant power speed regulation. Formula T=9550*P/N(rated speed). Therefore, in the case of f-type 50Hz(when the output power is the maximum), when n is large, attention should be paid to the fact that T is small to avoid accidents caused by T being too small and smaller than the load torque. In constant power speed regulation, speed regulation is achieved by reducing the magnetic flux to reduce the output torque and thus increase the speed, so it is also known as weak magnetic speed regulation.

        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標題-8.png 0755-81719517
        未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
        未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
        主站蜘蛛池模板: 亚洲国产日韩伦中文字幕| 精品国产乱一区二区三区| 欧美亚洲综合成人A∨在线| 夜色福利站www国产在线视频| 日本夜爽爽一区二区三区| 国产精品成人午夜福利| 一本色道久久—综合亚洲| 人妻人人妻a乱人伦青椒视频| 国产成人综合95精品视频| 国产99视频精品免费视频36| 欧美牲交videossexeso欧美| 成人午夜大片免费看爽爽爽| 国产在线一区二区在线视频| 色综合久久综合香蕉色老大 | 免费日韩av网在线观看| 精品无码国产自产拍在线观看蜜| 中文字幕色av一区二区三区| 欧美视频在线播放观看免费福利资源 | 日本伊人色综合网| 亚洲熟妇自偷自拍另类| 人妻丝袜av中文系列先锋影音| 久久99热只有频精品8| 免费无码又爽又刺激激情视频| 99热精品毛片全部国产无缓冲| 国产精品午夜福利视频| 亚洲国产精品国自拍av| 欧美人禽zozo动人物杂交| 成人av天堂网在线观看| 人妻精品动漫h无码| 男女激情一区二区三区| 欧美日韩精品一区二区三区高清视频| 一区二区三区精品偷拍| 免费大片黄国产在线观看| 中文字幕亚洲制服在线看| 西西人体大胆444WWW| 国语对白在线免费视频| 草草浮力影院| 亚洲日本精品国产第一区| 开心一区二区三区激情| 久久久精品人妻无码专区不卡| 精品精品亚洲高清a毛片|