        Key points for operation and maintenance of inverters in summer

        2023-05-20 11:38:46

        Summer is the frequent season of inverter faults. The key to ensuring long-term stable and reliable operation of the inverter is daily maintenance. In order to ensure that the inverter can operate stably in high temperature and hot summer, it is reduced due to improper maintenance or on-site operating environment. Unnecessary unplanned shutdowns are caused. During summer maintenance of the inverter, users must pay attention to the temperature of the inverter installation environment and regularly clean the dust inside the inverter to ensure the smoothness of the cooling air path. Strengthen patrol inspection to improve the surrounding environment of inverters, motors and lines. Check whether the connection terminals are tight, ensure the correct and reliable connection of each electrical return, and prevent unnecessary shutdown accidents.


        1. Confirmation of inverter installation environment


        1. Ambient temperature: Inverters generally require a minimum ambient temperature of -5 ° C and a maximum ambient temperature of 40 ° C. A large number of studies have shown that the failure rate of the inverter increases exponentially with increasing temperature, and the service life decreases exponentially with increasing temperature. If the ambient temperature increases by 10 degrees, the service life of the inverter will be halved. In summer, when the temperature is high, condensation will easily occur inside the inverter, and its insulation performance will be greatly reduced, and it may even cause a short circuit accident. The ventilation and heat dissipation of the inverter installation site should be strengthened.


        2. Summer is a rainy season, and rainwater should be prevented from entering the inverter (for example, rainwater entering the wind downwind outlet)


        3. Corrosive gas: If there is corrosive gas in the use environment, it will not only corrode the lead of the component, printed circuit board, etc., but also accelerate the aging of the plastic device and reduce the insulation performance; if there is acid or alkaline corrosion around the inverter Sexual gas, please provide targeted solutions according to the actual situation on site.


        4. Vibration and shock: When the inverter cabinet is subjected to mechanical vibration and shock, it will cause poor electrical contact. Therefore, after a period of operation, the equipment should be inspected and maintained.


        2. Matters needing attention in daily inspection


        1. Strengthen patrol inspection and arrange a special person to be responsible for the daily maintenance of the inverter;


        2. Operation data record: compile the operation record table of the inverter, regularly record the operation data of the inverter and the motor, including the inverter output frequency, output current, output voltage and other parameters, and compare and compare with reasonable data to facilitate the early detection of hidden troubles.


        3. Ensure that the ambient temperature of the inverter room is between -5 and 35 ° C. Set a special person to check whether the cooling fan on the top of the inverter cabinet is normal and whether the filter of the cabinet door is clogged. Ensure the cooling air path is unobstructed. The specific method is: put a standard thickness of A4 printing paper on the filter screen of the cabinet door, and the paper should be adsorbed on the air inlet window. In order to ensure the smoothness of the cooling air path, the filter screen should be cleaned once a week. If the site environment is dusty, the cleaning interval should be shortened.


        4. Environmental monitoring: When the temperature is high in summer, the ventilation of the frequency conversion installation site should be strengthened. Ensure that there is no excessive dust, acid, salt, corrosive and explosive gas in the surrounding air. The inverter should be protected from direct sunlight or placed near the heat source; summer is rainy season, and rainwater should be prevented from entering the inverter (such as rainwater downwind) Enter through the air outlet).


        5. Check the tightness of all electrical connections, check that there is no abnormal discharge trace in each circuit, no


        Strange smell, discoloration, cracks, damage, etc.


        6. The inverter room must be kept clean and tidy, and it should be cleaned at any time according to the actual situation on site.


        7. The ventilation and lighting of the inverter room must be good, and the ventilation and heat dissipation equipment (air conditioning, ventilation fan, etc.) can operate normally.


        three. Items that need maintenance after the inverter stops


        1. Use a vacuum cleaner with a plastic suction nozzle to thoroughly clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the device.


        2. Check the ventilation and lighting of the inverter room, and the ventilation equipment can operate normally.


        3. Check that the connections between the cables inside the inverter should be correct and reliable.


        4. Check that all grounding in the inverter cabinet should be reliable, and the grounding point is not rusty.


        5. The nuts of the internal cable connection of the inverter should be tightened again every six months.


        6. Check the tightness of all electrical connections, and check that there is no abnormal discharge trace in each circuit, no strange smell, discoloration, cracks, damage, etc.


        7. After each maintenance of the inverter, carefully check for missing screws and wires to prevent short-circuit accidents caused by small metal objects. In particular, after making major changes to the electrical circuit, ensure that the electrical connection cable is connected correctly and reliably to prevent 'reverse power transmission' accidents.


        Frequency converter manufacturer


        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標題-8.png 0755-81719517
        未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
        未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
        主站蜘蛛池模板: 欧美一区二区三区成人久久片 | 亚洲色成人一区二区三区| 亚洲熟妇熟女久久精品综合| 国产亚洲一在无在线观看| 亚洲大尺度无码专区尤物| 亚洲精品天堂一区二区| 国产精品电影久久久久电影网| 视频二区国产精品职场同事| 精品亚洲AⅤ无码午夜在线| 国产精品无码免费播放| 久久久久久亚洲精品| 91香蕉视频在线| 久久综合狠狠综合久久| 一本久道久久综合婷婷五月| 亚洲国产精品高清久久久| 亚洲精品国产精品不乱码| 日韩乱码视频一区二区三区| 无码日韩精品一区二区三区免费| 麻豆成人传媒一区二区| 久久久天堂国产精品女人| 国产男女猛烈无遮挡免费视频| 亚洲成人av在线高清| 无码国产精品一区二区AV | 天堂网在线观看| 在线观看无码av五月花| 日韩成人福利视频在线观看| 亚洲男女羞羞无遮挡久久丫| 国产午夜亚洲精品国产成人| 亚洲国产高清精品线久久| 亚洲色婷婷一区二区| 狠狠综合久久综合鬼色| 乌克兰少妇bbw| 四虎国产精品成人免费久久| 亚洲区日韩精品中文字幕| 亚洲小说乱欧美另类| 亚洲偷自拍国综合| 国产a级三级三级三级| 在线看免费无码的av天堂| 亚洲人视频在线观看| 欧美激情综合一区二区| 欧美日本激情|