        How about the performance of the frequency converter? It can be known when the multimeter is tested

        2023-05-20 12:15:12

        As we all know, frequency converter has many protection functions, such as over-current, over-voltage, overload protection and so on. With the continuous improvement of industrial automation, frequency converter has been widely used. This article will show you how to use a multimeter to measure the quality of the inverter.




        It should be noted that in order to ensure personal safety, the machine must be powered off, and the inverter input power lines R, s, t and output lines u, V, w must be removed before operation! First, set the multimeter to the "secondary pipe" position, and then test it by the red and black probes of the multimeter as follows:




        The black probe contacts the negative pole P (+) of the DC bus, and the red probe contacts R, s and t successively, recording the displayed value on the multimeter. Then contact the red probe with n (-), and the black probe with R, s and T in turn, and record the display value of the multimeter. If the six display values are basically balanced, it indicates that there is no problem with the rectifier or soft start resistance of the converter diode, otherwise the rectifier module or soft start resistance at the corresponding position is damaged, phenomenon: no display.




        The red probe contacts the negative pole P (+) of the DC bus, and the black probe contacts the U, V and W successively, recording the displayed value on the multimeter. Then contact the black probe with n (-), the red probe with u, V and W in turn, and record the display value of the multimeter. If the six display values are basically balanced, it indicates that there is no problem with the inverter IGBT module, otherwise, the IGBT inverter module at the corresponding position is damaged, phenomenon: no output or fault is reported.




        A power matching asynchronous motor is driven by a frequency converter to run without load, and the frequency f is adjusted, which starts to decrease from 50Hz to the lowest frequency.




        In this process, the ammeter is used to detect the no-load current of the motor. If the no-load current is stable in the process of frequency reduction and can be kept basically unchanged, it is a good inverter.




        The lowest frequency can be calculated in this way, (synchronous speed - rated speed) × pole logarithm P ÷ 60. For example, a 4-pole motor with a rated speed of 1470 rpm and a minimum frequency of (1500-1470) × 2 ÷ 60 = 1Hz.




        There is no problem with the soft start resistor. On the contrary, the rectifier module or the soft start resistor at the corresponding position is damaged. Phenomenon: no display.




        The red probe contacts the negative pole P (+) of the DC bus, and the black probe contacts the U, V and W successively, recording the displayed value on the multimeter. Then contact the black probe with n (-), the red probe with u, V and W in turn, and record the display value of the multimeter. If the six display values are basically balanced, it indicates that there is no problem in the inverter IGBT inverter module, otherwise, the IGBT inverter module at the corresponding position is damaged, phenomenon: no output or fault is reported.




        A power matching asynchronous motor is driven by a frequency converter to run without load, and the frequency f is adjusted, which starts to drop from 50Hz to the lowest frequency.




        In this process, the ammeter is used to detect the no-load current of the motor. If the no-load current is stable in the process of frequency reduction and can be kept basically unchanged, it is a good inverter.




        The lowest frequency can be calculated in this way, (synchronous speed - rated speed) × pole logarithm P ÷ 60. For example, for a 4-pole motor, the rated speed is 1470 rpm, the lowest frequency = (1500-1470) × 2 ÷ 60 = 1Hz.




        Identification of AC and DC solid-state relay: generally, beside the input and output ends of DC solid-state relay shell, there are "+" and "-" symbols, and the words "DC input" and "DC output" are marked. The AC solid-state relay can only mark "+" and "-" symbols on the input end, and the output end has no positive or negative difference.




        Discrimination between input end and output end: solid state relay without identification, multimeter R × 10K gear, to distinguish input end and output end by measuring the positive and negative resistance values of each pin respectively. When the forward resistance of two pins is small and the reverse resistance is infinite, the two pins are the input and the other two pins are the output. In a small resistance measurement, the black lead is connected with a positive input and the red lead is connected with a negative input.




        If the positive and negative resistances of both pins are 0, the solid-state relay is broken down. If the positive and negative resistance values of each pin of the solid-state relay are infinite, it means that the solid-state relay has been open circuit damaged.


        Shenzhen frequency converter


        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標(biāo)題-8.png 0755-81719517
        未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
        未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
        主站蜘蛛池模板: 亚洲一区二区成人| 亚洲av无码牛牛影视在线二区 | 国产精品综合一区二区三区 | 国产精品福利自产拍在线观看 | 日本三级理论久久人妻电影| 无码专区 人妻系列 在线| 亚洲天堂av日韩精品| 国产三级精品在线免费| 精品人妻一区二区三区蜜臀| 亚欧洲乱码视频一二三区 | 国产偷国产偷亚洲综合av| 亚洲欧美人成人让影院| 色噜噜亚洲黑人www视频| 久久蜜臀av一区三区| 亚洲成人资源在线观看| 久热这里只有精品视频六| 久久五十路丰满熟女中出| 亚洲国产AⅤ精品一区二区不卡| 国产成人黄色自拍小视频| 色伦专区97中文字幕| 亚洲综合久久一本伊一区| 亚洲人成网站77777在线观看| 777午夜福利理论电影网| 蜜臀av入口一区二区三区| 亚洲国产中文字幕在线视频综合| 波多野结衣av无码| 毛片免费观看天天干天天爽 | 亚洲第一福利视频导航| 色综合夜夜嗨亚洲一二区| 人妻久久久一区二区三区| 免费看婬乱a欧美大片| 国内精品伊人久久久久AV一坑 | 元码人妻精品一区二区三区9| 在线视频一区二区三区不卡| 老司机精品成人无码AV| 国产精品成人精品久久久| 大地资源免费视频观看| 欧美另类亚洲一区二区| 蜜臀av午夜精品福利| 亚洲产在线精品亚洲第一站一| 伊人精品成人久久综合97|