    How about the performance of the frequency converter? It can be known when the multimeter is tested

    2023-05-20 12:15:12

    As we all know, frequency converter has many protection functions, such as over-current, over-voltage, overload protection and so on. With the continuous improvement of industrial automation, frequency converter has been widely used. This article will show you how to use a multimeter to measure the quality of the inverter.




    It should be noted that in order to ensure personal safety, the machine must be powered off, and the inverter input power lines R, s, t and output lines u, V, w must be removed before operation! First, set the multimeter to the "secondary pipe" position, and then test it by the red and black probes of the multimeter as follows:




    The black probe contacts the negative pole P (+) of the DC bus, and the red probe contacts R, s and t successively, recording the displayed value on the multimeter. Then contact the red probe with n (-), and the black probe with R, s and T in turn, and record the display value of the multimeter. If the six display values are basically balanced, it indicates that there is no problem with the rectifier or soft start resistance of the converter diode, otherwise the rectifier module or soft start resistance at the corresponding position is damaged, phenomenon: no display.




    The red probe contacts the negative pole P (+) of the DC bus, and the black probe contacts the U, V and W successively, recording the displayed value on the multimeter. Then contact the black probe with n (-), the red probe with u, V and W in turn, and record the display value of the multimeter. If the six display values are basically balanced, it indicates that there is no problem with the inverter IGBT module, otherwise, the IGBT inverter module at the corresponding position is damaged, phenomenon: no output or fault is reported.




    A power matching asynchronous motor is driven by a frequency converter to run without load, and the frequency f is adjusted, which starts to decrease from 50Hz to the lowest frequency.




    In this process, the ammeter is used to detect the no-load current of the motor. If the no-load current is stable in the process of frequency reduction and can be kept basically unchanged, it is a good inverter.




    The lowest frequency can be calculated in this way, (synchronous speed - rated speed) × pole logarithm P ÷ 60. For example, a 4-pole motor with a rated speed of 1470 rpm and a minimum frequency of (1500-1470) × 2 ÷ 60 = 1Hz.




    There is no problem with the soft start resistor. On the contrary, the rectifier module or the soft start resistor at the corresponding position is damaged. Phenomenon: no display.




    The red probe contacts the negative pole P (+) of the DC bus, and the black probe contacts the U, V and W successively, recording the displayed value on the multimeter. Then contact the black probe with n (-), the red probe with u, V and W in turn, and record the display value of the multimeter. If the six display values are basically balanced, it indicates that there is no problem in the inverter IGBT inverter module, otherwise, the IGBT inverter module at the corresponding position is damaged, phenomenon: no output or fault is reported.




    A power matching asynchronous motor is driven by a frequency converter to run without load, and the frequency f is adjusted, which starts to drop from 50Hz to the lowest frequency.




    In this process, the ammeter is used to detect the no-load current of the motor. If the no-load current is stable in the process of frequency reduction and can be kept basically unchanged, it is a good inverter.




    The lowest frequency can be calculated in this way, (synchronous speed - rated speed) × pole logarithm P ÷ 60. For example, for a 4-pole motor, the rated speed is 1470 rpm, the lowest frequency = (1500-1470) × 2 ÷ 60 = 1Hz.




    Identification of AC and DC solid-state relay: generally, beside the input and output ends of DC solid-state relay shell, there are "+" and "-" symbols, and the words "DC input" and "DC output" are marked. The AC solid-state relay can only mark "+" and "-" symbols on the input end, and the output end has no positive or negative difference.




    Discrimination between input end and output end: solid state relay without identification, multimeter R × 10K gear, to distinguish input end and output end by measuring the positive and negative resistance values of each pin respectively. When the forward resistance of two pins is small and the reverse resistance is infinite, the two pins are the input and the other two pins are the output. In a small resistance measurement, the black lead is connected with a positive input and the red lead is connected with a negative input.




    If the positive and negative resistances of both pins are 0, the solid-state relay is broken down. If the positive and negative resistance values of each pin of the solid-state relay are infinite, it means that the solid-state relay has been open circuit damaged.


    Shenzhen frequency converter


    label

    QR code

    The public,

    Mobile station
    The public, Mobile station

    Contact

    未標題-8.png 0755-81719517
    未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
    未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

    Navigation

    Home          About

    Product      Case

    Solution      Service

    Job      News

    Contact          

    Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
    主站蜘蛛池模板: 亚洲最大的熟女水蜜桃AV网站| 亚洲尤码不卡av麻豆| 少妇激情一区二区三区视频| 无人去码一码二码三码区| 精品国产成人一区二区| 亚洲中文一区二区av| 中文字幕人妻中出制服诱惑| 一区二区三区精品偷拍| 久久国产成人亚洲精品影院老金| 野外做受三级视频| 最近中文字幕国产精品| 国内不卡一区二区三区| 中文午夜乱理片无码| 深夜免费av在线观看| 亚洲av成人一区二区三区| 国产精品熟女一区二区三区| 久久亚洲精品人成综合网| 亚洲精品成人一二三专区| 激情综合色综合久久综合| www国产精品内射熟女| 四虎在线成人免费观看| 激情综合网五月婷婷| 国产免费视频一区二区| 欧美日韩v| 亚洲人成网站在线播放2019 | 无码射肉在线播放视频| 欧美另类图区清纯亚洲| 97久久超碰亚洲视觉盛宴| 精品乱码一区二区三四五区| 久热综合在线亚洲精品| 国产破外女出血视频| 九九在线精品国产| 国语精品自产拍在线观看网站| 久久精品一本到99热免费| 人妻中文字幕av资源站| 国产成人不卡一区二区| 国产综合久久亚洲综合| 久久热这里这里只有精品| 亚洲av永久无码精品网站| 特级做a爰片毛片免费看无码| 精品中文人妻在线不卡|