        How does the frequency converter control the motor speed?

        2023-05-20 13:30:44

        1. why can the rotation speed of the motor be changed freely?


        Motor rotation speed unit: r/min rotation times per minute, or rpm


        For example: 2 pole motor 50hz3000[r/min]


        4 pole motor 50hz1500[r/min]


        Conclusion: the rotating speed of motor is proportional to the frequency


        The rotation speed of induction AC motor (hereafter referred to as motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed according to the working principle of the motor. Since the pole value is not a continuous value (a multiple of 2, for example, the number of poles is 2, 4, 6), it is generally uncomfortable and the motor speed is adjusted by changing the value.


        In addition, the frequency can be adjusted outside the motor and then supplied to the motor, so that the motor rotation speed can be freely controlled.


        Therefore, the inverter with the purpose of controlling frequency is the best equipment for motor speed regulation equipment.


        n=60f/p

        n: Synchronization speed

        f: Power frequency

        p: Motor pole number


        Conclusion: changing frequency and voltage is the best method of motor control


        If only the frequency is changed without changing the voltage, the frequency reduction will cause the motor to be out of overvoltage (overexcitation), which may cause the motor to be burnt out. Therefore, the frequency converter must change the voltage at the same time. When the output frequency is above the rated frequency, the voltage can not be increased continuously, and the maximum voltage can only be equal to the rated voltage of the motor.


        For example, in order to reduce the rotation speed of the motor by half, the output frequency of the converter is changed from 50Hz to 25Hz, and the output voltage of the converter needs to be changed from 400V to about 200V


        2. what is the output torque of the motor when the rotation speed (frequency) of the motor changes?


        The starting torque and maximum torque of the inverter drive shall be less than that of the direct power frequency power supply


        The motor starts and accelerates greatly when power supply is supplied by power supply, and when using frequency converter, these shocks will be weaker. Direct starting of power frequency will produce a large starting current. When using frequency converter, the output voltage and frequency of the inverter are gradually added to the motor, so the starting current and impact of the motor are smaller.


        In general, the torque generated by the motor will decrease with the decrease of frequency (speed reduction). The actual data reduced will be explained in some frequency converter manuals.


        By using flux vector control converter, the shortage of torque in low speed motor will be improved, and enough torque can be output even in low speed area.


        3. When the frequency converter is adjusted to more than 50 Hz, the output torque of the motor will be reduced


        The motor is usually designed and manufactured according to the voltage of 50 Hz, and its rated torque is also given in this voltage range. Therefore, the speed regulation under the rated frequency is called constant torque speed regulation. (t = te, P < = PE)


        When the frequency converter output frequency is greater than 50 Hz frequency, the torque produced by the motor will decrease in a linear relationship inversely proportional to the frequency.


        When the motor runs at the frequency of more than 50 Hz, the size of the motor load must be considered to prevent the insufficient output torque of the motor.


        For example, the torque produced by a motor at 100Hz should be reduced to about half of the torque produced at 50Hz.


        Therefore, the speed regulation above the rated frequency is called constant power speed regulation. (P = UE * IE)


        4. Application of frequency converter above 50 Hz


        As we all know, for a specific motor, its rated voltage and rated current are constant.


        For example, the rated value of frequency converter and motor is 15kw / 380V / 30a, and the motor can work above 50 Hz.


        When the speed is 50 Hz, the output voltage of the inverter is 380V and the current is 30A. At this time, if the output frequency is increased to 60Hz, the maximum output voltage and current of the inverter can only be 380V / 30A. Obviously, the output power remains unchanged, so we call it constant power speed regulation


        What is the torque situation?


        Because P = WT (W: angular velocity, t: torque). Because P is constant, w increases, so the torque decreases accordingly.


        We can also look at it from another perspective


        Stator voltage U = e + I * r (I is current, R is electronic resistance, e is induced potential)


        It can be seen that when u and I are constant, e remains the same


        And E = k * f * x, (K: constant, F: frequency, X: flux), so when f is from 50 to > 60Hz, x will decrease correspondingly


        For the motor, t = k * I * x, (K: constant, I: current, X: flux), so the torque T decreases with the decrease of flux X


        At the same time, when I * r is very small when I * r is less than 50 Hz, when u / F = E / F is constant, the flux (x) is constant. The torque T is proportional to the current. This is why the overload (torque) capacity of the inverter is usually described by the over-current capacity of the converter, which is also called constant torque speed regulation (constant rated current --- > maximum torque constant)


        Conclusion: the output torque of the motor will decrease when the frequency of inverter increases from 50 Hz to above


        5. Other factors related to output torque


        The output current capacity of the inverter is determined by the heating and cooling capacity, which affects the output torque capacity of the inverter.


        Carrier frequency: in general, the rated current marked by frequency converter is the value with the highest carrier frequency, which can ensure continuous output under the highest ambient temperature. When the carrier frequency is reduced, the motor current will not be affected. But the heating of components will be reduced.


        Ambient temperature: as if not because of the detection of low ambient temperature on the inverter protection current value


        Altitude: the increase of altitude will affect the heat dissipation and insulation performance. Generally, it is not considered if the altitude is below 1000m. It is OK to reduce the capacity by 5% every 1000m


        Special frequency converter


        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標(biāo)題-8.png 0755-81719517
        未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
        未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號(hào):粵ICP備12045920號(hào)
        主站蜘蛛池模板: 国产成人a在线观看视频| 天天做天天爱夜夜爽导航| 成人午夜大片免费看爽爽爽| 农村国产毛片一区二区三区女 | 国产精品久久久国产盗摄| 亚洲熟女少妇乱色一区二区| 亚洲中文字幕国产精品| 久久狠狠高潮亚洲精品夜色| 一个人www在线视频免费| 日韩精品无遮挡在线观看| 免费无码又爽又刺激高潮的app| 日韩精品视频一区二区不卡| 亚洲色拍拍噜噜噜最新网站 | 国产经典三级在线| 国内久久人妻风流av免费| 亚洲av日韩av一区久久| 国产成人一区二区三区久久精品| 日本高清视频色WWWWWW色| 最新午夜国内自拍视频| 蜜桃久久精品成人无码av| 蜜臀av黑人亚洲精品| 日韩精品亚洲专在线电影| 日本女优在线观看一区二区三区| 亚洲av成人免费在线| 欧美日韩精品一区二区三区高清视频| 亚洲黄色成人在线观看| 草草线在成年免费视频2 | 婷婷丁香五月激情综合| 日韩中文字幕v亚洲中文字幕| 成年女人免费碰碰视频| 国产亚洲精品第一综合麻豆| 2021中文字幕亚洲精品 | 一本伊大人香蕉久久网手机| 成人aⅴ综合视频国产| 91中文字幕在线一区| 成人av午夜在线观看| 深夜宅男福利免费在线观看| 国产精品乱人伦一区二区 | 色熟妇人妻久久中文字幕| 久久99日韩国产精品久久99| 韩国午夜理论在线观看|