    How does the frequency converter control the motor speed?

    2023-05-20 13:30:44

    1. why can the rotation speed of the motor be changed freely?


    Motor rotation speed unit: r/min rotation times per minute, or rpm


    For example: 2 pole motor 50hz3000[r/min]


    4 pole motor 50hz1500[r/min]


    Conclusion: the rotating speed of motor is proportional to the frequency


    The rotation speed of induction AC motor (hereafter referred to as motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed according to the working principle of the motor. Since the pole value is not a continuous value (a multiple of 2, for example, the number of poles is 2, 4, 6), it is generally uncomfortable and the motor speed is adjusted by changing the value.


    In addition, the frequency can be adjusted outside the motor and then supplied to the motor, so that the motor rotation speed can be freely controlled.


    Therefore, the inverter with the purpose of controlling frequency is the best equipment for motor speed regulation equipment.


    n=60f/p

    n: Synchronization speed

    f: Power frequency

    p: Motor pole number


    Conclusion: changing frequency and voltage is the best method of motor control


    If only the frequency is changed without changing the voltage, the frequency reduction will cause the motor to be out of overvoltage (overexcitation), which may cause the motor to be burnt out. Therefore, the frequency converter must change the voltage at the same time. When the output frequency is above the rated frequency, the voltage can not be increased continuously, and the maximum voltage can only be equal to the rated voltage of the motor.


    For example, in order to reduce the rotation speed of the motor by half, the output frequency of the converter is changed from 50Hz to 25Hz, and the output voltage of the converter needs to be changed from 400V to about 200V


    2. what is the output torque of the motor when the rotation speed (frequency) of the motor changes?


    The starting torque and maximum torque of the inverter drive shall be less than that of the direct power frequency power supply


    The motor starts and accelerates greatly when power supply is supplied by power supply, and when using frequency converter, these shocks will be weaker. Direct starting of power frequency will produce a large starting current. When using frequency converter, the output voltage and frequency of the inverter are gradually added to the motor, so the starting current and impact of the motor are smaller.


    In general, the torque generated by the motor will decrease with the decrease of frequency (speed reduction). The actual data reduced will be explained in some frequency converter manuals.


    By using flux vector control converter, the shortage of torque in low speed motor will be improved, and enough torque can be output even in low speed area.


    3. When the frequency converter is adjusted to more than 50 Hz, the output torque of the motor will be reduced


    The motor is usually designed and manufactured according to the voltage of 50 Hz, and its rated torque is also given in this voltage range. Therefore, the speed regulation under the rated frequency is called constant torque speed regulation. (t = te, P < = PE)


    When the frequency converter output frequency is greater than 50 Hz frequency, the torque produced by the motor will decrease in a linear relationship inversely proportional to the frequency.


    When the motor runs at the frequency of more than 50 Hz, the size of the motor load must be considered to prevent the insufficient output torque of the motor.


    For example, the torque produced by a motor at 100Hz should be reduced to about half of the torque produced at 50Hz.


    Therefore, the speed regulation above the rated frequency is called constant power speed regulation. (P = UE * IE)


    4. Application of frequency converter above 50 Hz


    As we all know, for a specific motor, its rated voltage and rated current are constant.


    For example, the rated value of frequency converter and motor is 15kw / 380V / 30a, and the motor can work above 50 Hz.


    When the speed is 50 Hz, the output voltage of the inverter is 380V and the current is 30A. At this time, if the output frequency is increased to 60Hz, the maximum output voltage and current of the inverter can only be 380V / 30A. Obviously, the output power remains unchanged, so we call it constant power speed regulation


    What is the torque situation?


    Because P = WT (W: angular velocity, t: torque). Because P is constant, w increases, so the torque decreases accordingly.


    We can also look at it from another perspective


    Stator voltage U = e + I * r (I is current, R is electronic resistance, e is induced potential)


    It can be seen that when u and I are constant, e remains the same


    And E = k * f * x, (K: constant, F: frequency, X: flux), so when f is from 50 to > 60Hz, x will decrease correspondingly


    For the motor, t = k * I * x, (K: constant, I: current, X: flux), so the torque T decreases with the decrease of flux X


    At the same time, when I * r is very small when I * r is less than 50 Hz, when u / F = E / F is constant, the flux (x) is constant. The torque T is proportional to the current. This is why the overload (torque) capacity of the inverter is usually described by the over-current capacity of the converter, which is also called constant torque speed regulation (constant rated current --- > maximum torque constant)


    Conclusion: the output torque of the motor will decrease when the frequency of inverter increases from 50 Hz to above


    5. Other factors related to output torque


    The output current capacity of the inverter is determined by the heating and cooling capacity, which affects the output torque capacity of the inverter.


    Carrier frequency: in general, the rated current marked by frequency converter is the value with the highest carrier frequency, which can ensure continuous output under the highest ambient temperature. When the carrier frequency is reduced, the motor current will not be affected. But the heating of components will be reduced.


    Ambient temperature: as if not because of the detection of low ambient temperature on the inverter protection current value


    Altitude: the increase of altitude will affect the heat dissipation and insulation performance. Generally, it is not considered if the altitude is below 1000m. It is OK to reduce the capacity by 5% every 1000m


    Special frequency converter


    label

    QR code

    The public,

    Mobile station
    The public, Mobile station

    Contact

    未標(biāo)題-8.png 0755-81719517
    未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
    未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

    Navigation

    Home          About

    Product      Case

    Solution      Service

    Job      News

    Contact          

    Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
    主站蜘蛛池模板: 欧美另类精品xxxx人妖| 国产精品自产拍在线播放| 视频一区视频二区视频三| 亚洲熟妇色xxxxx欧美老妇| 成在线人永久免费视频播放| 成av人电影在线观看| 亚洲国产美女精品久久久| 国产精品第一页一区二区| 蜜臀人妻精品一区二区免费| 日韩精品一区二区三区色| 亚洲欧美日韩国产精品一区二区| 亚洲中文字幕伊人久久无码| 国产极品精品自在线不卡| 国产一码二码三码区别| 国产在线精品一区二区夜色| 国产日韩精品中文字幕| 亚洲国产精品无码一区二区三区| 亚洲夂夂婷婷色拍ww47| 99精品国产一区在线看| 日韩精品 在线一区二区| 国产一区二区黄色激情片| 亚洲欧洲日产国码久在线| 亚洲欧美在线观看品| 国产日产免费高清欧美一区| 元码人妻精品一区二区三区9 | 色婷婷日日躁夜夜躁| 亚洲人午夜精品射精日韩| 亚洲精品综合久中文字幕| 亚洲国产成人午夜在线一区| 亚洲av成人精品日韩一区| 国产av一区二区三区久久| 九九热免费精品视频在线| 国产成人免费永久在线平台 | 无码专区 人妻系列 在线| 97人妻免费碰视频碰免| 人妻少妇精品久久| 日韩人妻系列无码专区| 国产欧美丝袜在线二区| 无码人妻斩一区二区三区| 69天堂人成无码免费视频| 亚洲日本精品一区二区|