        The bearing capacity of high-voltage inverter for external faults and the fault recovery time of equipment

        2023-05-20 13:35:30

        The influence of external fault on input side, such as bus voltage drop caused by external power grid fault, on the operation of high voltage inverter. A power plant unit in Guangdong Province once had such an accident: due to the transient fault of the external power grid, the auxiliary power bus voltage flickered and dropped, leading to the shutdown of the auxiliary frequency converter. Although the fault of the external power grid was removed quickly, the important auxiliary equipment driven by the frequency converter stopped, which led to the unit load rejection. Therefore, the re start function of instantaneous power failure should be a reliable guarantee to improve the bearing capacity of external fault of high-voltage inverter of auxiliary equipment of power plant.


        The influence of external faults on the output side, such as cable breakdown and short circuit, single-phase grounding or even phase to phase short-circuit fault on high-voltage inverter. The high-voltage inverter shall be equipped with single-phase grounding fault detection function, and set alarm or trip protection according to site conditions. According to statistics, there are about 20 sets of phase to phase short circuit fault caused by insulation damage of high-voltage motors in Guangdong Province every year. Although the relative probability is small, the impact of short-circuit current on the equipment of high-voltage inverter with extremely limited over-current capacity is huge, which may lead to serious fault of equipment damage. The bearing capacity and protection technology of high voltage inverter to output phase to phase short circuit is an important factor to be considered in equipment selection and equipment safety assurance.


        Equipment faults can be divided into two types: one is the fault that can be recovered instantly. Once the fault occurs, it can recover itself in a short time. The frequency conversion device with automatic speed tracking function can significantly improve the operation ability and reliability under such fault conditions. Some of the high-voltage inverters in Guangdong Province are frequently shut down when lightning strikes in thunderstorm season;


        The other is the recovery time of the device after permanent failure. The power unit modularization can replace the standby module in a short time, so that the equipment can resume operation in a short time.


        General purpose frequency converter


        label

        QR code

        The public,

        Mobile station
        The public, Mobile station

        Contact

        未標(biāo)題-8.png 0755-81719517
        未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
        未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

        Navigation

        Home          About

        Product      Case

        Solution      Service

        Job      News

        Contact          

        Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
        主站蜘蛛池模板: 中文字幕av日韩有码| 亚洲一区二区三区久久蜜桃| 亚洲免费福利在线视频| 四虎成人免费视频在线播放| 麻豆国产AV剧情偷闻女邻居内裤| 国产伦码精品一区二区| 国产精品无码av不卡| 国产成人综合色就色综合| 人妻精品动漫H无码中字| 无码免费大香伊蕉在人线国产| 深夜视频国产在线观看| 亚洲乱理伦片在线观看中字| 桃花岛亚洲成在人线AV| 久章草在线毛片视频播放| 成人做受120秒试看试看视频| 好男人好资源WWW社区| 欧美黑人XXXX性高清版 | 四虎库影成人在线播放| 高清性欧美暴力猛交| 在线日韩日本国产亚洲| 国产精品嫩草99av在线| 亚洲色大成网站www看下面| 国产精品爆乳奶水无码视频免费| 亚洲精品自拍视频在线看| 亚洲欧美日韩国产精品专区| A级孕妇高清免费毛片| 红杏av在线dvd综合| 国产成人无码午夜视频在线播放| 精品人妻无码中文字幕在线| a在线免费| 两个人的视频www免费| 久久不卡精品| 四虎成人精品在永久在线| 天天在线看无码AV片| 成年无码av片在线蜜芽| 精品人妻一区二区三区蜜臀| 国产欧美日韩精品丝袜高跟鞋| 国产中文字幕在线精品| 久女女热精品视频在线观看| 国产a在亚洲线播放| 国产av永久无码天堂影院|